Primary tabs

FREE SHIPPINGFree shipping on all orders over 100000 INR.

Corrosion Inhibitor Multifunctional Closed Chilled Systems

0
No votes yet

Product Qty Per Unit: 
25.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Visakhapatnam, Vijayawada, Kakinada, Gangavaram, Krishnapatnam, Rawa, Nellore, Rajahmundry
Premium Quality Alkaline Corrosion Inhibitor blend for Metal protection inside the CLOSED circulating system
Product Description: 

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

 

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.
 

RXSOL-40-4011-025 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-025 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

Product Application: 

RXSOL-40-4011-025 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-025 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

Product Procedure: 

Compatible with Feeders, piping and valves should be made of steel, polyethylene, or PVC. This Treatment can be controlled by a nitrite test.

The recommended dosage of RXSOL-40-4011-025 is 15.6-23.4 l/m3 of system capacity or 60.6-87 RXSOL-40-4011-025 of system capacity in all systems. Clean up the system if the system becomes contaminated with iron. Maintain 600-750 ppm nitrite as NO2. RXSOL-40-4011-025  is intended for industrial use only. It should not be fed to potable water systems

Product Note: 

◦Very effective to Controls corrosion on brass, aluminum, steel, and stainless steel
◦Extends equipment life & Improves overall equipment efficiency

Product Technical Specification: 

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.

Product pack size: 
Alkaline Corrosion Inhibitor blend for Metal protection inside the CLOSED circulating system. RXSOL closed water treatment chemicals are designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. Alkaline inhibitor for closed cooling systems available in 30 Kg Liquid and 220 Kg Drum PACKS.
Product alias: 
<p> Accepta 2807, Korodex 8574, TRASAR TRAC 102, CORRSHIELD NT 4293, HYDREX 2853, Corrosion Inhibitor Multifunctional closed/chilled systems 30 Kg Ltr</p>
Remarks: 

Keep in a tightly closed container in storage closed area . Recommended storage temperature is below 500C
 

SKU:
RXSOL-40-4011-025
Title:
Corrosion Inhibitor Multifunctional Closed Chilled Systems