Primary tabs

FREE SHIPPINGFree shipping on all orders over 100000 INR.

Corrosion Inhibitor for Boiler Neutralizer

0
No votes yet

Product Qty Per Unit: 
25.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Visakhapatnam, Vijayawada, Kakinada, Gangavaram, Krishnapatnam, Rawa, Nellore, Rajahmundry
Category: 
Boiler Chemicals-42

Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2

Product Description: 

Corrosion Inhibitor for Boiler Neutralizer Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2 throughout a condensate system. Protects boiler surfaces by forming an iron tannate film.
A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.

Product Application: 

Corrosion Inhibitor for Boiler Neutralizer is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition
Used in medium and high-pressure boilers including ultra high-pressure boilers.

Fields Of Application:-
Corrosion Inhibitor for Boiler Neutralizer is an effective neutralizing type corrosion inhibitor & oxygen scavanger  for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe2O3 (rust) to organic iron compound protect further IRON rust reaction .

Operating Process:-
RXSOL-CC72 neutralizes the acid components of feed water.The proportion of 
Corrosion Inhibitor for Boiler Neutralizer depends upon the Carbon dioxide content of the condensate. Basically Corrosion Inhibitor for Boiler Neutralizer neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition.  It also protects copper based metals.

PRODUCT APPLICATION
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.
Product Procedure: 

Corrosion Inhibitor for Boiler Neutralizer condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of Corrosion Inhibitor for Boiler Neutralizer is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.

Product Note: 
  • Easy to use liquid treatment.
  • Neutralizes the acids occurring in the condensate system.
  • Less maintenance required. Lower operating costs and increased reliability.
  • Volatilizes and carries over with the steam and so is recycled. Dosage is economical and efficient.
  • Simple test to determine level of treatment.
  • Used for protection of condensate and feed water systems in boiler systems of all pressures.
Product Technical Specification: 

We carry a complete line of condensate treatment chemicals.  Condensate treatment chemicals are used to increase the condensate pH, thus reducing corrosion to the entire boiler steam system.  The most common product is a tri-blend amine of cyclohexylamine, morpholine, and diethylaminoethanol (DEAE) neutralizing amines, although we do have standard RXSOL products or we can custom blend to your needs.
RXSOL-50-5005-DCM1          10% DEAE, 10% Cyclo, 10% Morpholine   
RXSOL-50-5005-DCM2          20% DEAE, 20% Cyclo, 20% Morpholine   
RXSOL-50-5005-C                  20% Cyclohexylamine    
RXSOL-50-5005-D                  20% DEAE    
RXSOL-50-5005-M                  20% Morpholine   
RXSOL-50-5005-C5                50% Cyclohexylamine    
RXSOL-50-5005-D                  50% DEAE  
RXSOL-50-5005-M5                50% Morpholine    
  

PRODUCT INTRODUCTION
Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3
HANDLING & STORAGE
Keep away from heat and sources of ignition.
Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.
Use proper PPE during handling.
PRODUCT APPLICATION
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.
PROPERTIES
Appearance
Clear Colorless Liquid
Purity ( by GC ) , %
99.8 Min
Specific Gravity @25°C
0.9995 ± 0.05
Moisture (by KF) , %
0.3 Max
PACKAGING
Packed in drums or in ISO TANKS on request.

 
 

Product pack size: 
20, 25, 35, 50, 210 Ltrs Mail us to get factory sale discounted price. Amines that provide great protection and neutralization of acidic gases, Corrosion control in condensate and feed water systems. Protects boiler surfaces by forming an iron tannate film.
Product alias: 
<p> Green CC, RXSOL 9-150 / SLCC-A, Care Treat-4, MARICHEM C.C.I.TM, CCT 102, Maxtreat 3330, DM-530, Condensate Treatment 9-150, BWT QC4, pH CONTROLLER AMINE base, NEUTRALIZING AMINE AGENT JCF 2005 RP-01A, Aquameen 1150D, Condensate Control, HYDREX 1646, Amerzine 25 Ltr PACK</p>
Remarks: 

Corrosion Inhibitor for Boiler Neutralizer alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  
Corrosion Inhibitor for Boiler Neutralizer  near a heating equipment.

SKU:
RXSOL-42-5005-020
Title:
Corrosion Inhibitor for Boiler Neutralizer