Primary tabs

FREE SHIPPINGFree shipping on all orders over 100000 INR.

Scale Hardness Stabilizer

0
No votes yet

Product Qty Per Unit: 
25.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Visakhapatnam, Vijayawada, Kakinada, Gangavaram, Krishnapatnam, Rawa, Nellore, Rajahmundry
Category: 
RO Chemicals-33

Seawater Treatment and dispersing agent formulated Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid.

Product Description: 

Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid.  Scale Hardness Stabilizer Hardness Control is specialized Water treatment product to KEEP  water Clear and Clean SLUDGE FREE.

Product Application: 

RXSOL-33-5027-025 Scale Hardness Stabilizer is basically Polyacrylate phosphates combination with synthetic polymers.  Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary.  The tool is designed to maintain the cleanliness of the system at unstable as feedwater.

To be most effective to prevent corrosion and scaling RXSOL-33-5027-025 Scale Hardness Stabilizer should be constantly adding to the system with a dosing devices.  Less preferable to use gravitational dosing device, because  preparation can evaporate when the water returns into the tank cascade.

Product Procedure: 

Regularly enter solutions RXSOL-33-5027-025 Scale Hardness Stabilizer with a dosing device in feedwater recirculation outlet below which returns cascading water in the tank.  If there is no recirculation of feedwater, the RXSOL-33-5027-025 Scale Hardness Stabilizer should be submitted in suction tube feeding pump.  When using gravity dispenser the RXSOL-33-5027-025 Scale Hardness Stabilizer should be fed to the point of feed water tank or in cascade. 

Product Note: 

RXSOL-33-5027-025 Scale Hardness Stabilizer supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. RXSOL-33-5027-025 Scale Hardness Stabilizer to be diluted in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand.  The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system.  For standard operating systems the dosage RXSOL-33-5027-025 Scale Hardness Stabilizer is about 1 liter a day.

Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the RXSOL-33-5027-025 Scale Hardness Stabilizer. The recommended initial dose of 2.5 to 5 liters per tonne of water system.  After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage.  Low quality feedwater demands increase quantities of preparation.

The main objective of the program - to prevent fouling.  The most effective way to fight c deposits is to use distilled water feed.  RXSOL-33-5027-025 Scale Hardness Stabilizer created for removing water hardness instability.

Blowdown

Purge procedure is necessary for the effectiveness of any treatment program and system watershall be in accordance recommendations manufacturer's instructions.  Purging is required to remove the precipitate dissolved and suspended solids.  Normal regular purging with sufficient neutral of conductivity 700  micromho.  A higher rate of conductivity (above 700  micromho) frequency blowdown should be increased.  Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.

Product Technical Specification: 

 

Appearance

: Clear liquid

Specific gravity at 25 º C (77 º F)

: 1.2

Fire

: off

Freezing temperature

: -6.6 º C (20 º F)

pH

: 5-7

Stability after freeze / that

: yes

Product pack size: 
Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid. to control sludge. USES of RXSOL Scale Hardness Stabilizer Hardness Control provide tolerance of feedwater quality fluctuations. The ready stock of Scale Hardness Stabilizer Hardness Control is in 25, 50, 220 Ltr packing.
Product alias: 
<p> Hardness Stabilizer POC 3000</p>
Remarks: 

Did you know, how to keep system scale and corrosion free, water CLEAR and Sludge free?

RXSOL-33-5027-025 Scale Hardness Stabilizer contains Polycarboxylate Phosphate and synthetic low molecular wt polymer  to control sludge which results in the clean boiler water. USES of RXSOL-33-5027-025 control Hardness and provide tolerance of feedwater quality fluctuations.

Chemically one part of The RXSOL-33-5027-025 polymers  keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during cleaning and maintenance operation.


While Other part of Phosphate which is used in RXSOL-33-5027-025 serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.

USES of RXSOL-33-5027-025 during sea water treatment, can help and keep WATER CLEAN and CLEAR.

SKU:
RXSOL-33-5027-025
Title:
Scale Hardness Stabilizer