Corrosion Inhibitor Zinc Based

← Back to all products
Sewage Chemicals Treatment-40

Corrosion Inhibitor Zinc Based

SKU: RXSOL-40-4029-025
Corrosion Inhibitor with Zinc salts and Polyphosphates
Pack Size / Specification:
Corrosion Inhibitor for Open Cooling Circulating System available in 25 Kg packing.
Enquire About This Product →

Technical Specifications

PHYSICAL CHARACTERICS 
Appearance   : Clear Liquid - Also available in PINK colour
Specific Gravity  : 1.10 to 1.20
Flash Point  : Non Flammable 
Freezing Point  : 0 Degrees Cent. 
 
Property Specification
Appearance Clear to light amber liquid
Odour Mild acidic
pH (as supplied) 3.0 - 5.5
Specific Gravity (25°C) 1.25 - 1.45
Solubility Completely miscible in water
Flash Point Non-flammable
Stability Stable under normal storage conditions

Application & Dosage

Corrosion Inhibitor OPEN Cooling System  scientifically formulated to keep clean open recirculating systems  and also prevent from scale formation . Chemically Corrosion Inhibitor OPEN Cooling System  will disperse scale and corrosive products, silt etc and can be used as an anti-foulant along with other treatments. 

Excellent scale inhibition for a variety of applications including cooling circuits, boilers and RO units.

It is widely used in Boilers, cooling water and membranes

Where can RXSOL Corrosion Inhibitor Zinc Based be used?

  • Closed loop cooling water systems
  • Industrial heat exchangers and chillers
  • Hydrostatic testing of pipelines and vessels
  • Temporary rust protection of metal surfaces
  • Process water systems in chemical and petrochemical plants
  • Equipment storage preservation fluids

RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  is highly concentrated cooling water treatment product, Its small dosage from 0.5 – 1 liter per 10 Tons of Cooling Water. The source of water also directly affecting its dosage as  The dosage depends on the quality of the supply water ( Total hardness and Chloride content as low as possible) .  Control is by simple colourismetric test. 

Optimum result of COOLING SYSTEM can be obtained by maintaing pH level 8 to 8.5 and Total phosphate level should be maintained between 20 and 30 ppm. 

Feel free to ask for RXSOL PHOSPHATE TEST KIT, RXSOL HARDNESS TEST KIT, RXSOL CHLORIDE TEST KIT. We are keeping full range of TEST KIT.

 

DOSAGE BASED ON ZINC LEVELS

ACTIVE ZINC value in system after dosing should be maintained at 1 to 5 ppm.

Therefore, total product dosage must be in the range of 20-80 ppm to prevent scaling and corrosion

Correct dosage can be understood taking into account water quality and other factors.

Rapid protection against corrosion is achieved by pre-treating the system with between three and five times the normal maintenance dosage for seven to ten days. The maintenance dosage is then applied to the recirculating water at all times.

Related Information