Primary tabs
BIOCIDE MICRO for Water Treatment
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system.
BIOCIDE MICRO for Water Treatment is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.
it is a strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-020 establish a buffer action to control very rapid algae growth.
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors . For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems.
Microbiocide based on Organo sulphur compound, for use in open recircurculating systems.
* Highly effective
* Broad spectrum activity
* Economical and easy to use
* Compatible with other treatments.
Features and Benefits
- High performance biocidal adjunct used for generating hypobromous acid.
- Effective at low concentrations
- Effective at high pH
- Controls a wide spectrum of bacteria, algae and fungi
- Simple to control
- Will inhibit formation of biofilms
Specification
Appearance | Colourless to brown hazy |
Odor | Odorless |
Flammability | Non Flammable |
pH | 5-9 |
Density | 1.1 |
Solubility | Completely soluble |
For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 at some point in the system to ensure uniform mixing.
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020
NOTE: Badly fouled systems should be cleaned before treatment.
Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 per 1000 gallon of makeup water).
NOTE : Badly fouled systems must be cleaned before initial treatment.
INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.
SUBSEQUENT DOSE: When microbial control is evident, add 100 ml - 100 ml MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 per 3000 Ltr of water in the system.