ADJUNCT Hardness Controller

← Back to all products
Deck cabin galley Maintenance-25

ADJUNCT Hardness Controller

SKU: RXSOL-25-5006-025

Hardness Control is a white dry powder Phosphate Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge. Disodium phosphate pure neutral grade  used in BOILER with other Boiler Water treatment chemicals concentrated alkaline liquid to prevent calcium scale deposits. 

Application

Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown. Disodium phosphate as a scale controller used in lowpressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar) also in boiler water treatment program for highpressure steam generating systems (60-84 bar).

Used for boilers and water softening.

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Technical Specification

The use of Disodium phosphate treatment in BOILER converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.
Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :White powder
Corrosive action  :NonE
pH 1% solution   :8.8
Flash point         :None

Pack Size / Specification:
Hardness Phosphate Control protects against Deposition and corrosion of boiler systems reduces efficiency, and increases fuel and water consumption, and usage of RXSOL Hardness Phosphate Control regularly enhances boiler efficiency. This product is available in 25, 50, and 210 kg
Enquire About This Product →